Recreational & Sports Facility Lighting
Lights run in recreational facilities for extended periods of time, resulting in high electricity bills. Even when patrons aren’t in the facility, lights may be left on for a janitorial crew. By installing energy efficient lights you can reduce energy costs and heat gain. Installing sensors controlled by occupancy and natural light levels can reduce your costs.
Because recreational facilities typically have high energy consumption, upgrading to energy efficient technologies can significantly reduce their energy and operating costs – both immediately and for years to come.
Green, OH
Reballast (14) 2×4 F40T12 four lamp wrap fixtures with new ballasts and F28T8 lamps.
Remove (35) 1000w MH fixtures and install (21) F54T5HO 16 lamp fixtures at 336w.
Remove (25) 1000w MH fixtures and install (14) F54T5HO 12 lamp fixtures at 168w.
Replace (10) 60w incandescent lamps with 8w LED’s.
Total kWh Savings: 152,556
CO2 Reduced (lbs.): 161,226
Annual Energy Consumption Savings: $15,256
Total Annual Savings: $17,182
Coventry, OH
Retrofit (112) 2×4 F40T12 two lamp fixtures with new ballasts and F28T8 lamps.
Retrofit (2) 2×4 F40T12 four lamp fixtures with new ballasts and F28T8 lamps.
Retrofit (35) 2×2 F40T12 two lamp fixtures with ballasts and F32T8/U/6 lamps.
Retrofit (30) 2×4 F40T12 six lamp fixtures with new ballasts and F28T8 lamps.
Remove (10) 400w HID fixtures and install new 84w Wallpacks.
Replace (49) 120w PAR38’s with 18w PAR30 LED’s.
Replace (6) existing incandescent exit signs with new LED exit signs.
Total kWh Savings: 77,369
CO2 Reduced (lbs.): 81,089
Energy Consumption Savings: $7,737
Total Annual Savings: $9,907
Broadview Heights, OH
Remove (59) 1000w MH fixtures.
Install (28) new 16 lamp direct/indirect fixtures with F54T5HO lamps.
Install (14) new 12 lamp direct/indirect fixtures with F54T5HO lamps.
Relamp (416) existing F32T8 lamps with lower wattage F28T8 lamps.
Relamp (60) existing F54T5 lamps with lower wattage F54T5 lamps.
Retrofit (4) 250w MH fixtures with 24w PAR30 LED’s.
Replace (1) 23w incandescent with 14w A19 LED.
Replace (3) 60w incandescents with 14w A19 LED’s.
Replace (2) 65w BR30’s with 15w BR30 LED’s.
Replace (10) 50w MR16’s with 6w MR16 LED’s.
Retrofit (19) existing recessed can fixtures with 15w LED inserts.
Replace (2) existing incandescent ext signs with new LED exit signs.
Install (4) ceiling mounted sensors.
Total Watts Reduced: 33,405
Annual Energy Savings: $25,942
Total 5 Year Savings: $142,767
Cost of Waiting Per Month: $2,161.81
Interested in how USIlluminations can help save your facility money on the utility bill? Contact USIlluminations today!!